Start with the power bill. Eight NVIDIA RTX PRO 6000 Blackwell cards at their full 600W rating is 4.8kW of GPU alone; add the CPU, memory, drives and conversion losses and RENDA quotes about 6.4kW for a typical full load. Put that in a 4U box and drop it into a 19-inch rack that was planned around air cooling, and the conventional answer is facility work first: piping, a coolant distribution unit, downtime and capital. RENDA and Nexalus invert that: put the liquid loop inside the server so an air-cooled room can take high-density GPUs without new facility water. StorageReview covered the Nova8 on November 23, 2026.

Self-contained liquid: cold plates, micropumps and an internal radiator, all in the chassis

Official interior: eight liquid-cooled RTX PRO 6000 GPUs, CPU cold plate and micropump loops
Official interior: eight liquid-cooled RTX PRO 6000 GPUs, CPU cold plate and micropump loops

The Nova8 uses Nexalus jet-impingement cooling: jets of coolant strike the cold plate directly over the hottest regions instead of sweeping along channels. GPUs get single-slot liquid blocks, the CPU a jet-impingement block; ten micropumps drive five redundant loops and sixteen fans in push-pull pairs move air across an internal radiator. The vendors say the server keeps running if a single part fails, and quick-disconnects let parts be swapped without draining the loop. What they have not published is how much throughput survives with a pump or fan out of service.

One physical fact is easy to miss: without the optional rear quick-connects, the internal radiator rejects heat into the room, so the room's air handling still absorbs the full ~6.4kW. "Self-contained liquid" solves chip-to-coolant, not room-to-outside. The optional rear connectors export heat as water up to 60°C for reuse or a dry cooler — that is the option that actually relieves the facility.

Vendor testing: 55,000 tokens/s, but read the configuration

The NVIDIA RTX PRO 6000 Blackwell accelerator used (official render)
The NVIDIA RTX PRO 6000 Blackwell accelerator used (official render)

RENDA tested Llama 3.3 70B Instruct in NVFP4 on TensorRT-LLM, one replica per GPU, 512 concurrent requests, 256 in / 256 out tokens, all eight GPUs capped at 600W. The best tuned run hit 54,564 tokens/s; a one-hour run averaged 53,984. The company claims ~20% more throughput than comparable air-cooled systems and 8.6 tokens/W (~22% better efficiency). But the reference is a published air-cooled result (45,527 tokens/s, 7.03 tokens/W) from a dual-EPYC server running two replicas per GPU and 8,192 concurrent users, and the Nova8 used Workstation Edition cards — different serving configurations, not a same-condition uplift. At 8.6 tokens/W the best run implies ~6.3kW, consistent with the 6.4kW estimate (calculated). All vendor-reported; StorageReview did not audit.

Configuration and deployment: one EPYC, 2TB, 2+2 power

Nova8 pairs a single AMD EPYC (model undisclosed) with up to 2TB DDR5 RDIMM and eight U.2 PCIe Gen5 NVMe drives; four 3kW Titanium supplies in 2+2 redundancy; Linux, NVIDIA drivers and TensorRT-LLM preinstalled, compatible with vLLM/NIM. After-sales runs through UNICOM Engineering. RENDA is operated by Overclockers UK (Pro Gamers Group); Nexalus is a Cork, Ireland liquid-cooling specialist. Pricing and shipping are undisclosed; pre-order or a remote Test Drive is available.

For older Pearl River Delta rooms the pitch is clear: rack space, power and room air, no facility water loop. But three Nova8s is ~19kW in 12U, beyond what many air-cooled rows are provisioned to remove; inlet limits, airflow, dimensions and weight are unpublished. Get the per-rack kW, inlet temperature and airflow numbers, re-test throughput on your own models, then decide how many to buy. It fits "want dense GPUs without a facility rebuild" as a bridge, not a replacement for true facility-level liquid cooling.

Source

StorageReview (2026-11-23): https://www.storagereview.com/news/renda-nova8-eight-600w-rtx-pro-6000-gpus-4u-self-contained-liquid-cooling . Throughput/efficiency are vendor-reported.